MS6 REDUCED VOLTAGE STARTER
Page 22
7.7 DC INJECTION BRAKING
DC injection braking provides smooth braking for AC induction motors.
DC injection offers adjustable braking because it is current controlled.
Unlike a mechanical brake, an electrical brake will never wear out.
The brake operates by injecting DC current in two phases of the motor to rapidly decelerate
it to zero speed.
When stop is commanded the Opal Pro shuts off for 2 seconds to allow the voltage across
the motor to drop. The DC injection current is then applied at a level set in parameter 1104
for the amount of time set in parameter 1105. It does not provide zero speed sensing,
although if two wire control is used terminal 4 can be used to disable the DC injection
(activated = enabled).
If braking is released before the motor stops, the motor will coast to rest. If the braking
remains on after the motor stops, the DC supply will provide a holding brake.