OPAL SS6 Reduced Voltage Starters
Page 6
2.0 SPECIFICATIONS
2.1 POWER RATING
POWER 3ø, 200-600VAC, 50/60 Hz
CONTROL 115 VAC@50 Hz or 120 VAC@60 Hz, 12VA (fans are extra)
RATING See Section 2.2
All models have 1600V PIV SCR's
CONTACTS Run and fault relay contacts rated at 0.2A, 115VAC
PROTECTION Short circuit by HRC fuses or circuit breaker (supplied upon request)
Voltage surge protection by MOV's across the SCR's
2.2 MAXIMUM RATINGS
OPAL
MODEL
HORESEPOWER
230V 460V 575V
SS6-15 5 10 15
SS6-30 10 25 30
SS6-50 20 40 50
SS6-80 30 60 75
SS6-125 50 100 125
SS6-200 75 150 200
SS6-360 150 300 350
SS6-500 200 400 500
SS6-600 250 500 600
SS6-800 300 600 800
2.3 SERVICE CONDITIONS
ELEVATION For altitudes in excess of 2000 meters / 6600 feet above sea level, all
assemblies must be derated 1% for every 100 meters / 330 feet above
AMBIENT Do not install in areas where ambient temperature falls below
TEMPERATURE 0°C / 32°F or exceeds 40 °C / 104°F